| Name | Grooved Director & Tongue Tie – Plain Point |
| Lead Time | 0-3 days |
| Competitor | ;MB336R;SU10820450;180250;180-250;MDS2011011;091512;09-1512;0915-12;BN003R;SU10820500;180251;180-251;091513;09-1513;0915-13;BN004R;SU10820550;180252;180-252;40885;301055;30-1055;091514;09-1514;0915-14;BN006R;AC1074;AC10-74;SU10820600;180253;180-253;091516;09-1516;1074;166613;SU10820-600;0915-16;091518;09-1518;0915-18;180255;180-255;0915-20;0915-12_0915-20; |
| Specialty | General Instruments-Suction Tubes, Needles & Probes – Grooved Directors |
| Material Finish | Stainless Steel |
| Grade | Premium Operating Room |
| Units of Measurement | Each |
| Manufacturer | Shazira International |
| Sterility | Non-Sterile |
| Usage | Reusable |
Tongue Tie – Plain Point
Tongue Tie – Plain Point
stainless steel, plain point
Grooved Director and Tongue Tie contains a plain point at one end and a butterfly-shaped director on the other end. This stainless steel instrument is typically used during a frenotomy to lift the tongue back and expose the frenulum. The frenulum would rest on the grooved part of the director and then be cut with iris scissors. Depending on the patient, this device is offered in various lengths.
SKU:
SI-01-877
Category: Suction Tubes, Needles & Probes
Description
Reviews (0)
Be the first to review “Tongue Tie – Plain Point” Cancel reply
Related products
Probe W/ Eye – usa pattern
SKU:
SI-01-873
usa pattern
Probe With Eye is a USA Pattern that is available in stainless steel or sterling silver material and a variety of different lengths. The slender rod contains an eye opening on one end near the handle that may be useful if ligatures need to be carried. Additionally, this probe is typically used during general surgeries to examine body tissues or for situations such as detecting foreign bodies.
Mayo Vein Stripper
SKU:
SI-01-869
Mayo Vein Stripper
15-3/8" (39.0 cm)
Mayo Vein Stripper is 15 3/8" long instrument with a short grip handle and a long rod with a circular jaw. This vein stripper is typically used in procedures that require the removal of varicose veins because the use of this instrument is quicker and there are fewer infections that appear on the patient. Multiple inner diameters of the ring are available according to the type of vein that needs to be stripped.
Coakley Antrum Trocars
SKU:
SI-01-859
Coakley Antrum Trocars
w/ cannula & irrigating extension, strong curve, 6-1/4" (15.9 cm)
Coakley Antrum Trocars serves the purpose of withdrawing fluid from a part of the body, such as the sinuses. A cannula and irrigating extension are offered with the trocars to further assist the process. This instrument is protected by the Surgical manufacturer warranty on defects in materials and workmanship.
Double-Ended Probe – Silver
SKU:
SI-01-862
Double-Ended Probe - Silver
sterling silver
Double-Ended Probe is made from sterling silver material to be better fitted for general purposes due to its hardness. Additionally, the blunt points on either end help to examine body cavities or tissues without trauma. Depending on the type or location of the examination, this probe is offered in several lengths.
Cooley Graft Suction Tube
SKU:
SI-01-860
Cooley Graft Suction Tube
8.0 mm wide round perforated tip, 7" (17.8 cm) working length, 12" (30.5 cm) overall length
Cooley Graft Suction Tube is a popular instrument used in various surgical operations to eliminate and clear bodily fluids that may obstruct the view of the surgical site. For this reason, the distal end of the tube contains a piece that is attached to a suction machine in order to provide the suction power for the instrument to perform. The other end contains a long tube that has an 8.0 mm wide tip, which allows it to extract greater amount of fluid away from the area.
Frazier Suction Tube
SKU:
SI-01-863
Frazier Suction Tube
angled, w/ finger cut-off, 4" (10.2 cm) working length
Frazier Suction Tube has an angled tube and is available in a variety of different sizes and widths depending on the operation. This tube has a finger cut-off on a 4" working length and performs similar to a pump with a suction force. The purpose of this suction force is to be used in general operations in which materials or fluid, typically blood, need to be removed to provide a cleaner working area.
Grooved Director & Tongue Tie – Probe Point
SKU:
SI-01-868
Grooved Director & Tongue Tie - Probe Point
stainless steel, probe point
Grooved Director and Tongue Tie is a stainless steel instrument that contains a probe point on one end typically used to examine the mouth in young children. The other end consists of a flat butterfly-shaped end. In frenotomy procedures that require stabilizing the tongue, the grooved director can assist in this process and provide a better view for the surgeon. Different sizes are available to accommodate different cases.
Suction Tube
SKU:
SI-01-876
Suction Tube
w/ removable tip
Yankauer Suction Tube comes with a tip that can be removeved to allow access to tighter spaces. If these tips get lost, however, they can be purchased separately to be used only for the Yankauer suction tube. This device is also long in length and can range from 10 ¼" to 18" depending on the operation. The handle of this device contains an end that can be connected to a suction source in order to provide the suction power needed to remove fluids or debris away from the surgical site.

Reviews
There are no reviews yet.